Multi-site solar & BESS fleet overview

Priority 1 · F004SYN-BYG-INV04·Biyagama 4.5 MWp Industrial Rooftop (BOOT)·Reported 12s ago

Biyagama 4.5MWp Inv-04 — Carbonized Stäubli MC4-Evo2 DC Connector on MPPT-7 String-14 & IGBT Phase-B Thermal Derating (AFCI Trip 2064)

MPPT-7 S14: 61.2% PR (AFCI Code 2064)POA Irrad: 940 W/m²IGBT-B Temp: 84.8 °CRiso: 0.42 MΩRef: Huawei SUN2000-100KTL Manual §6.4

Synogen Multi-Site Fleet — Domestic, Commercial, Industrial & Utility Sites

42.8 MWp · BOOT / Roof Rental / NetPlus
4.5 MWp C&I · 67%

Biyagama Industrial Rooftop

SYN-BYG-INV04

BOOT · Biyagama EPZ

String-14 PR61.2%
IGBT-B Temp84.8 °C
Riso / AFCI0.42 MΩ (2064)
3.2 MWp C&I · 94%

Katunayake Apparel Rooftop

SYN-KTN-TRK01

Roof Rental · Katunayake

Active Gen2.74 MW
Site PR85.8%
Irradiance910 W/m²
10 MWp + 5 MWh · 82%

Hambantota Ground & BESS

SYN-HMB-BESS02

Utility PPA + BESS

Cell ΔV (M07)148 mV
Coolant ΔP2.4 bar
BESS SoC72.4% (3.6 MWh)
2.2 MWp Float · 91%

Kurunegala Floating Solar

SYN-KRN-SCB03

Floating Microgrid O&M

Active Gen1.82 MW
Site PR86.4%
Water Temp27.8 °C
850 kWp + EV · 96%

Rajagiriya Carport & EV Hub

SYN-RJG-EVC02

Synogen HQ · Carport & EV

Carport Gen712 kW
EV Fast Load340 kW (6 CCS2)
Charger Eff.96.8%
640 kWp (28x) · 98%

Colombo & Negombo Domestic

SYN-DOM-CMB07

Installment · 5–35 kW Homes

Cluster Gen548 kW
Home BESS SoC88.5%
CEB NetPlus28/28 Online

Active O&M work order queue (Industrial, BESS & Domestic)

WOTask & siteEngineerPriorityAction
W102

String-14 AFCI Arc Fault (Code 2064) & MC4-Evo2 Re-Termination

Biyagama 4.5MWp Inv-04

critical
W101

CATL 5MWh BESS Rack 02 Active Cell Balancing & Chiller Flush

Hambantota 5MWh BESS-02

high
W100

Domestic NetPlus Cluster — 28-Home Smart Meter & Hybrid Battery Audit

Colombo-07 Domestic Cluster

low
W099

Kurunegala 2.2MWp Floating Solar Robotic Panel Wash & SPD Swap

Kurunegala 2.2MWp Float-SCB03

medium
W098

Rajagiriya HQ 180kW EV Supercharger & Carport Harmonic Filter Check

Rajagiriya 850kWp EV-Carport

medium
RadiantIQ CMMS synchronized · 2 HV/DC LOTO permits activeLog inverter/BESS reading

Synogen & RadiantIQ O&M field specialists

4 available
NP

Nuwan Perera

Lead Solar PV & String Inverter Specialist

KS

Kasun Silva

RadiantIQ SCADA & String Telemetry Engineer

CB

Chaminda Bandara

HV/LV Grid Interconnection & EV Infrastructure Engineer

TF

Tharaka Fernando

BESS & Hybrid Energy Storage Specialist

RK

Ruwan Kumara

Aerial Thermography & Domestic/C&I O&M Lead

Recent fleet SCADA events

RadiantIQ Historian
AFCI-2064CRITICAL AFCI ALARM: Biyagama 4.5MWp Inv-04 String-14 Arc Fault (Code 2064) & IGBT-B at 84.6°C
RADIANT-AIRadiantIQ RCA generated — 93% probability carbonized MC4-Evo2 plug on MPPT-7 String-14
WO-102Work Order #W102 assigned to Nuwan Perera (1100V DC LOTO-DC-INV04 active)
BMS-R02Hambantota 5MWh BESS-02 LFP cell ΔV drift detected (148 mV on Rack 02 Module 07)